Home English Philosophie Übersicht Produktglossar Neuigkeiten Energiemarkt aktuell Kontakt Impressum

Artikel 60-122
Öle und Fette Gas Kohle und Koks Biomasse Strom Chemikalien Projektierung Service-Angebote

 

Nach oben

 

MCT 60/40

Product Datasheet

Item number: 60-122

 

 

Specification of MCT 60/40

 

Characteristic

 

Inspection Method

 

Unit

 

Specified Range

 

Acid value

DGF C-V 2

 

mg KOH/g

<= 0,1

Saponification value

DGF C-V 3

mg KOH/g

325 - 345

Iodine value

DGF C-V 11d

g I/100g

<= 0,5

Hydroxyl value

Ph. Eur. 2.5.3

mg KOH/g

<= 5

Colour APHA

DGF C-IV 4

 

<= 60

Water content

DGF C-III 13a

%

<= 0,1

Fatty acid C06

Ph. Eur. 2.4.22

%

<= 0,5

Fatty acid C08

Ph. Eur. 2.4.22

%

55 - 65

Fatty acid C10

Ph. Eur. 2.4.22

%

35 - 45

Fatty acid C12

Ph. Eur. 2.4.22

%

<= 1,5

Fatty acid C14

Ph. Eur. 2.4.22

%

<= 0,5

Odour

AAWBAN401071

 

neutral

Taste

AAWBAN401071

 

typical

Identity

Ph. Eur. Monographie

 

corresponds

Clearness of liquids

Ph. Eur. 2.2.1

 

corresponds

Opalescence of liquids

Ph. Eur. 2.2.2

 

corresponds

Cloud point

DGF D-III 3

°C

<= -5

Peroxide value

DGF C-VI 6a

meq O2/kg

<= 1

Unsaponifiables

DGF C-III 1a

%

<= 0,5

Ash

Ph. Eur. 2.4.16

%

<= 0,1

Refractive index

DGF C-IV 5

 

1,440 - 1,452

Alkal. reac. subst.

Ph. Eur. Monographie

ml

<= 0,15

Density 20°C

DGF C-IV 2a

g/cm³

0,93 - 0,96

Viscosity 20°C

DGF C-IV 7b

mPas

25 - 32

Heavy metals

Ph. Eur. 2.4.8

ppm

<= 10

Chromium

Ph. Eur. 2.2.23

ppm

<= 0,05

Copper

Ph. Eur. 2.2.23

ppm

<= 0,1

Lead

Ph. Eur. 2.2.23

ppm

<= 0,1

Nickel

Ph. Eur. 2.2.23

ppm

 <= 0,1

Tin

Ph. Eur. 2.2.23

ppm

<= 0,1

 

Not to be recorded on CoA (guaranteed but not determined for each batch):

  •  Chromium, Copper, Lead, Nickel, Tin (These values are tested two times a year.)

  •  Cloud point, Peroxide value, Unsaponifiables, Refractive index, Density, Alkal. reac. subst., Ash, Viscosity, Heavy metals (These values are tested monthly.)

 

 

Disclaimer

This document, or any answers or information provided herein by UCY business services & trading GmbH, does not constitute a legally binding obligation of UCY business services & trading GmbH. While the descriptions, designs, data and information contained herein are presented in good faith and believed to be accurate, it is provided for your guidance only. Because many factors may affect processing or application/use, we recommend that you make tests to determine the suitability of a product for your particular purpose prior to use. It does not relieve our customers from the obligation to perform a full inspection of the products upon delivery or any other obligation. NO WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH, OR THAT THE PRODUCTS, DESIGNS, DATA OR INFORMATION MAY BE USED WITHOUT INFRINGING THE INTELLECTUAL PROPERTY RIGHTS OF OTHERS. IN NO CASE SHALL THE DESCRIPTIONS, INFORMATION, DATA OR DESIGNS PROVIDED BE CONSIDERED A PART OF OUR TERMS AND CONDITIONS OF SALE.

 


 

 

 

 

UCY Energy Group

 

 

 

Zögern Sie nicht uns für Fragen aller Art zu kontaktieren: info@ucy-energy.com - Impressum
Copyright © 1999-2021 UCY Energy - UCY business services & trading GmbH